5 ESSENTIAL ELEMENTS FOR DP50RB

5 Essential Elements For Dp50rb

5 Essential Elements For Dp50rb

Blog Article

one.two.2 Warning Labels Warning Labels This means You should very carefully read through this manual prior to use machine. The next labels certainly are a. Do not area the unit on a sloped surface area. If not the out there once the procedure unit may perhaps slide, resulting in particular injury or even the system is effective With all the cellular malfunction.

iZoom™ permits precise viewing of graphic from length iWorks™ Protocol helps standardize workflow and minimize exam occasions

Simply click Concur and Continue to accept cookies and go on to the location or click More Information to see thorough descriptions of the categories of cookies and opt for no matter whether to just accept selected cookies when on the internet site.

Be aware: Be sure that you may pull out and drive in to the IO board sockets vertically when pulling out and assembling the IO board assembly around the posture of your cope with. Clear away panhead screws with washers M3X6 (4) utilized to safe the IO board, after which you might get out the IO board. Web page 116 Clear away panhead screws with washers (2 M3X6) that are fastened on the principle device, get out the higher baffle and after that pull out two cables connecting the primary board to the facility module assembly.

Site one hundred forty five Clear control panel Applications: dry soft fabric, delicate soapy h2o  Approach:  Use dry delicate cloth to clean the surface with the program. In the event the system is soiled, moisten the soft cloth with delicate soapy water and wipe off any stains. Use dry comfortable fabric to remove any dampness and permit all difficult surfaces to wholly air-dry. Webpage 146: Clean up The Peripherals

Usually do not use any cables other than the cables furnished Together with the gadget by Mindray. 3. Use the cable furnished with This method to attach the printer. Other cables may perhaps cause electrical shock. Web site fifteen: Mechanical Basic safety

Overall performance Exam five.5.1 Exam Approach Resolution Detection depth Geometric Posture Accuracy Blackout location test Document the Examination pictures 5.five.two Test Written content The image utilised here is only for reference, stay with the impression influence in the actual Take note: situation. Needs: Screen: set the contrast and brightness in the clinical software worth (or the default status) Procedure ecosystem: darkish area, simulating the clinical software natural environment. Site 76 In situation that the transverse resolution screening targets are horizontally displayed, history the negligible length of two targets which can be clearly recognized. Repeat the operation over for your transverse resolution tests targets at other depths. As demonstrated in determine under. Axial resolution ... Website page seventy seven When using the convex probe, keep the transverse resolution screening targets to NOTE: be shown close to the midline. When using a linear probe with steer functionality, tend not to activate the steer perform when perform the transverse resolution examination. Zoom within the area where the targets Found if needed. The diameter from the goal place at a certain depth is equal for the transverse resolution within the depth. Web page 78 5.

five.2.three Geometric positioning accuracy Longitudinal geometric positioning precision  Exam Step: Do changes as how in screening the maximum depth. Record the space by 20mm Just about every section within the longitudinal targets line utilizing the measurement caliper; Find the value with the greatest mistake (to 20mm), compute the precision using the system under The measurement caliper needs to be positioned in the higher edge of the focus on, Notice:... Web page seventy nine Transverse geometric positioning precision  Test Action: Deal with the scan surface area with the phantom with h2o or pair gel, Carefully Make contact with the probe While using the scan surface area Modify the depth, earning the transverse targets for being shown in the picture. Change the main target point for being posited beside the transverse targets (the typical is not very clear) Alter parameters like get, TGC, making Every single transverse targets for being Obviously displayed. Webpage 80 five.5.two.four Blackout Spot Take a look at Phase: Protect the scan floor in the phantom with water or pair gel, Carefully Speak to the probe Along with the scan floor Modify the depth in a decrease value, and established the focus at the closest place to the scan floor. Lower the worth of parameters like AP, Achieve until finally the background sound just may be found. Website page 81: Software package Improve And Routine maintenance

Cookies are essential to the appropriate performing of the web site. To help your knowledge, we use cookies to recall log-in details and supply protected log-in, collect figures to optimize web site features, and supply information customized towards your pursuits.

Aid 4D probe; figure out the probe by using the ID code; change the 4D drive sign by way of the  electrical relay to produce the 4D probe function Usually. four.two.2 Primary board The main board can be divided into two sections: front-end of the key board and again-conclusion of the principle board.

Once you end the scanning plus the image seize, you should energy off the procedure and disconnect the system from the AC power source, then pull out AC electric power cables. Site 109: Battery Connecting Board

Mindray’s new era of black & white ultrasound procedure, DP-fifty Professional, is equipped with Highly developed imaging systems permitting deeper penetration and more quickly impression acquisition with better resolution.

Cut off cable ties connecting the most crucial unit to the display by diagonal slicing pliers, and after that pull out the corresponding cable plugs.

Content material Approach Check out the battery periodically : a) Check out Dp50rb login if battery is often charged Usually when electrical power-on: That the current ability is one hundred% or capacity improves just after a short time indicates the battery may be billed Generally.

Report this page